IBM Tivoli Storage Area Network Manager : (Record no. 76514)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 11071nam a22004933i 4500 |
001 - CONTROL NUMBER | |
control field | EBC3306753 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | MiAaPQ |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20240729124922.0 |
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS | |
fixed length control field | m o d | |
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION | |
fixed length control field | cr cnu|||||||| |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 240724s2001 xx o ||||0 eng d |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER | |
International Standard Book Number | 9780738499970 |
Qualifying information | (electronic bk.) |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER | |
Canceled/invalid ISBN | 9780738499970 |
035 ## - SYSTEM CONTROL NUMBER | |
System control number | (MiAaPQ)EBC3306753 |
035 ## - SYSTEM CONTROL NUMBER | |
System control number | (Au-PeEL)EBL3306753 |
035 ## - SYSTEM CONTROL NUMBER | |
System control number | (CaPaEBR)ebr10112853 |
035 ## - SYSTEM CONTROL NUMBER | |
System control number | (OCoLC)932363930 |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | MiAaPQ |
Language of cataloging | eng |
Description conventions | rda |
-- | pn |
Transcribing agency | MiAaPQ |
Modifying agency | MiAaPQ |
050 #4 - LIBRARY OF CONGRESS CALL NUMBER | |
Classification number | TK5105.86 -- .I432 2001eb |
082 0# - DEWEY DECIMAL CLASSIFICATION NUMBER | |
Classification number | 004.6 |
100 1# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Redbooks, IBM. |
245 10 - TITLE STATEMENT | |
Title | IBM Tivoli Storage Area Network Manager : |
Remainder of title | A Practical Introduction. |
250 ## - EDITION STATEMENT | |
Edition statement | 1st ed. |
264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE | |
Place of production, publication, distribution, manufacture | Durham : |
Name of producer, publisher, distributor, manufacturer | I B M, |
Date of production, publication, distribution, manufacture, or copyright notice | 2001. |
264 #4 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE | |
Date of production, publication, distribution, manufacture, or copyright notice | ©2001. |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 1 online resource (460 pages) |
336 ## - CONTENT TYPE | |
Content type term | text |
Content type code | txt |
Source | rdacontent |
337 ## - MEDIA TYPE | |
Media type term | computer |
Media type code | c |
Source | rdamedia |
338 ## - CARRIER TYPE | |
Carrier type term | online resource |
Carrier type code | cr |
Source | rdacarrier |
505 0# - FORMATTED CONTENTS NOTE | |
Formatted contents note | Front cover -- Contents -- Figures -- Tables -- Notices -- Trademarks -- Preface -- The team that wrote this redbook -- Become a published author -- Comments welcome -- Summary of changes -- September 2003, Second Edition -- Part 1 Introduction -- Chapter 1. Introduction to Storage Area Network management -- 1.1 Why do we need SAN management? -- 1.1.1 Storage management issues today -- 1.1.2 Current generation of SAN management: spreadsheets and paper -- 1.2 New tools for SAN management are needed -- 1.2.1 Storage management components -- 1.2.2 Standards and SAN management tools -- 1.2.3 Discovery -- 1.2.4 Outband management -- 1.2.5 Inband management -- 1.2.6 Why you might use both inband and outband discovery -- 1.2.7 Formal standards for outband management -- 1.2.8 Formal standards for inband management -- 1.2.9 The future of SAN management standards -- 1.2.10 Summary -- Chapter 2. Introduction to IBM Tivoli Storage Area Network Manager -- 2.1 Highlights: What's new in Version 1.2 -- 2.1.1 Discovery of iSCSI -- 2.1.2 Event Detection and Fault Isolation (ED/FI - SAN Error Predictor) -- 2.1.3 IBM Tivoli Enterprise Data Warehouse (TEDW) -- 2.1.4 IBM Tivoli SAN Manager on AIX -- 2.1.5 Embedded WebSphere -- 2.1.6 Operating system support -- 2.1.7 Other changes -- 2.2 IBM Tivoli SAN Manager overview -- 2.2.1 Business purpose of IBM Tivoli SAN Manager -- 2.2.2 Components of IBM Tivoli SAN Manager -- 2.2.3 Supported devices for Tivoli SAN Manager -- 2.3 Major functions of IBM Tivoli SAN Manager -- 2.3.1 Discover SAN components and devices -- 2.3.2 Deciding how many Agents will be needed -- 2.3.3 How is SAN topology information displayed? -- 2.3.4 How is iSCSI topology information displayed -- 2.4 SAN management functions -- 2.4.1 Discover and display SAN components and devices -- 2.4.2 Log events -- 2.4.3 Highlight faults. |
505 8# - FORMATTED CONTENTS NOTE | |
Formatted contents note | 2.4.4 Provide various reports -- 2.4.5 Launch vendor management applications -- 2.4.6 Displays ED/FI events -- 2.4.7 Tivoli Enterprise Data Warehouse (TEDW) -- 2.5 Summary -- Part 2 Design considerations -- Chapter 3. Deployment architecture -- 3.1 Overview -- 3.2 Fibre Channel standards -- 3.2.1 Interoperability -- 3.2.2 Standards -- 3.3 Hardware overview -- 3.3.1 Host Bus Adapter -- 3.3.2 Cabling -- 3.4 Topologies -- 3.4.1 Point-to-point -- 3.4.2 Arbitrated loop -- 3.4.3 Switched fabrics -- 3.5 IBM Tivoli SAN Manager components -- 3.5.1 DB2 -- 3.5.2 IBM Tivoli SAN Manager Console (NetView) -- 3.5.3 Tivoli SAN Manager Agents -- 3.5.4 Tivoli SAN Manager Server -- 3.5.5 SAN physical view -- 3.6 Management -- 3.6.1 Inband management -- 3.6.2 Outband management -- 3.7 Deployment considerations -- 3.7.1 Tivoli SAN Manager Server -- 3.7.2 iSCSI management -- 3.7.3 Other considerations -- 3.7.4 Tivoli SAN Manager Agent (Managed Host) -- 3.8 Deployment scenarios -- 3.8.1 Example 1: Outband only -- 3.8.2 Example 2: Inband only -- 3.8.3 Example 3: Inband and outband -- 3.8.4 Additional considerations -- 3.9 High Availability for Tivoli SAN Manager -- 3.9.1 Standalone server failover -- 3.9.2 Summary -- Part 3 Installation and basic operations -- Chapter 4. Installation and setup -- 4.1 Supported operating system platforms -- 4.2 IBM Tivoli SAN Manager Windows Server installation -- 4.2.1 Lab environment -- 4.2.2 Preinstallation tasks -- 4.2.3 DB2 installation -- 4.2.4 Upgrading DB2 with Fix Pack 8 -- 4.2.5 Install the SNMP service -- 4.2.6 Checking for the SNMP community name -- 4.2.7 IBM Tivoli SAN Manager Server install -- 4.2.8 Verifying the installation -- 4.3 IBM Tivoli SAN Manager Server AIX installation -- 4.3.1 Lab environment -- 4.3.2 Installation summary -- 4.3.3 Starting and stopping the AIX manager -- 4.3.4 Checking the log files. |
505 8# - FORMATTED CONTENTS NOTE | |
Formatted contents note | 4.4 IBM Tivoli SAN Manager Agent installation -- 4.4.1 Lab environment -- 4.4.2 Preinstallation tasks -- 4.4.3 IBM Tivoli SAN Manager Agent install -- 4.4.4 Configure the Agent service to start automatically -- 4.5 IBM Tivoli SAN Manager Remote Console installation -- 4.5.1 Lab environment -- 4.5.2 Preinstallation tasks -- 4.5.3 Installing the Console -- 4.5.4 Check if the service started automatically -- 4.6 IBM Tivoli SAN Manager configuration -- 4.6.1 Configuring SNMP trap forwarding on devices -- 4.6.2 Configuring the outband agents -- 4.6.3 Checking inband agents -- 4.6.4 Performing initial poll and setting up the poll interval -- 4.7 Tivoli SAN Manager upgrade to Version 1.2 -- 4.7.1 Upgrading the Windows manager -- 4.7.2 Upgrading the remote console -- 4.7.3 Upgrading the agents -- 4.8 Tivoli SAN Manager uninstall -- 4.8.1 Tivoli SAN Manager Server Windows uninstall -- 4.8.2 Tivoli SAN Manager Server AIX uninstall -- 4.8.3 Tivoli SAN Manager Agent uninstall -- 4.8.4 Tivoli SAN Manager Remote Console uninstall -- 4.8.5 Uninstalling the Tivoli GUID package -- 4.9 Silent install of IBM Tivoli Storage Area Network Manager -- 4.9.1 Silent installation high level steps -- 4.9.2 Installing the manager -- 4.9.3 Installing the agent -- 4.9.4 How to install the remote console -- 4.9.5 Silently uninstalling IBM Tivoli Storage Area Network Manager -- 4.10 Changing passwords -- Chapter 5. Topology management -- 5.1 NetView navigation overview -- 5.1.1 NetView interface -- 5.1.2 Maps and submaps -- 5.1.3 NetView window structure -- 5.1.4 NetView Explorer -- 5.1.5 NetView Navigation Tree -- 5.1.6 Object selection and NetView properties -- 5.1.7 Object symbols -- 5.1.8 Object status -- 5.1.9 Status propagation -- 5.1.10 NetView and IBM Tivoli SAN Manager integration -- 5.2 Lab 1 environment description -- 5.3 Topology views -- 5.3.1 SAN view. |
505 8# - FORMATTED CONTENTS NOTE | |
Formatted contents note | 5.3.2 Device Centric View -- 5.3.3 Host Centric View -- 5.3.4 iSCSI discovery -- 5.3.5 MDS 9000 discovery -- 5.4 SAN menu options -- 5.4.1 SAN Properties -- 5.5 Application launch -- 5.5.1 Native support -- 5.5.2 NetView support for Web interfaces -- 5.5.3 Non-Web applications -- 5.5.4 Launching IBM Tivoli Storage Resource Manager -- 5.5.5 Other menu options -- 5.6 Status cycles -- 5.7 Practical cases -- 5.7.1 Cisco MDS 9000 discovery -- 5.7.2 Removing a connection on a device running an inband agent -- 5.7.3 Removing a connection on a device not running an agent -- 5.7.4 Powering off a switch -- 5.7.5 Running discovery on a RNID-compatible device -- 5.7.6 Outband agents only -- 5.7.7 Inband agents only -- 5.7.8 Disk devices discovery -- 5.7.9 Well placed agent strategy -- 5.8 Summary -- Part 4 Advanced operations -- Chapter 6. NetView Data Collection, reporting, and SmartSets -- 6.1 Overview -- 6.1.1 SNMP and MIBs -- 6.2 NetView setup and configuration -- 6.2.1 Advanced Menu -- 6.2.2 Copy Brocade MIBs -- 6.2.3 Loading MIBs -- 6.3 Historical reporting -- 6.3.1 Creating a Data Collection -- 6.3.2 Database maintenance -- 6.3.3 Troubleshooting the Data Collection daemon -- 6.3.4 NetView Graph Utility -- 6.4 Real-time reporting -- 6.4.1 MIB Tool Builder -- 6.4.2 Displaying real-time data -- 6.4.3 SmartSets -- 6.4.4 SmartSets and Data Collections -- 6.4.5 Seed file -- Chapter 7. Tivoli SAN Manager and iSCSI -- 7.1 What is iSCSI? -- 7.2 How does iSCSI work? -- 7.3 IBM Tivoli SAN Manager and iSCSI -- 7.3.1 Functional description -- 7.3.2 iSCSI discovery -- 7.4 Summary -- Chapter 8. SNMP Event notification -- 8.1 Overview -- 8.2 Introduction to Tivoli NetView -- 8.2.1 Setting up the MIB file in Tivoli NetView -- 8.3 Introduction to IBM Director -- 8.3.1 Event forwarding from IBM Tivoli SAN Manager to IBM Director -- Chapter 9. ED/FI - SAN Error Predictor. |
505 8# - FORMATTED CONTENTS NOTE | |
Formatted contents note | 9.1 Overview -- 9.2 Error processing -- 9.3 Configuration for ED/FI - SAN Error Predictor -- 9.4 Using ED/FI -- 9.4.1 Searching for the faulted device on the topology map -- 9.4.2 Removing notifications -- Part 5 Maintenance -- Chapter 10. Protecting the IBM Tivoli SAN Manager environment -- 10.1 IBM Tivoli SAN Manager environment -- 10.1.1 IBM Tivoli NetView -- 10.1.2 Embedded IBM WebSphere Application Server -- 10.1.3 IBM Tivoli SAN Manager Server -- 10.1.4 IBM Tivoli SAN Manager Agents -- 10.2 IBM Tivoli Storage Manager integration -- 10.2.1 IBM Tivoli Storage Manager -- 10.2.2 Setup for backing up IBM Tivoli SAN Manager Server -- 10.2.3 Tivoli Storage Manager server configuration -- 10.2.4 Tivoli Storage Manager client configuration -- 10.2.5 Additional considerations -- 10.3 Backup procedures -- 10.3.1 Agent files -- 10.3.2 Server files -- 10.3.3 ITSANMDB Database -- 10.4 Restore procedures -- 10.4.1 Restore Agent files -- 10.4.2 IBM Tivoli SAN Manager Server files -- 10.4.3 ITSANMDB database -- 10.5 Disaster recovery procedures -- 10.5.1 Windows 2000 restore -- 10.5.2 ITSANMDB database restore -- 10.6 Database maintenance -- Chapter 11. Logging and tracing -- 11.1 Overview -- 11.2 Logging -- 11.2.1 Server logs -- 11.2.2 Manager service commands -- 11.2.3 Service Manager -- 11.2.4 Agent logs -- 11.2.5 Remote Console logging -- 11.2.6 Additional logging for NetView -- 11.2.7 ED/FI - SAN Error Predictor -- 11.3 Tracing -- 11.4 SAN Manager Service Tool -- 11.4.1 Exporting (snapshot) -- 11.4.2 Importing (restore) -- Part 6 Tivoli Systems Management Integration -- Chapter 12. Tivoli SAN Manager and TEC -- 12.1 Introduction to Tivoli Enterprise Console -- 12.2 Lab environment -- 12.3 Configuring the Rule Base -- 12.4 Configuring TEC Event Console -- 12.5 Event format -- 12.6 Configuring Tivoli SAN Manager event forwarding. |
505 8# - FORMATTED CONTENTS NOTE | |
Formatted contents note | 12.6.1 Set the event destination. |
588 ## - SOURCE OF DESCRIPTION NOTE | |
Source of description note | Description based on publisher supplied metadata and other sources. |
590 ## - LOCAL NOTE (RLIN) | |
Local note | Electronic reproduction. Ann Arbor, Michigan : ProQuest Ebook Central, 2024. Available via World Wide Web. Access may be limited to ProQuest Ebook Central affiliated libraries. |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name entry element | IBM Cluster systems management. |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name entry element | Parallel processing (Electronic computers). |
655 #4 - INDEX TERM--GENRE/FORM | |
Genre/form data or focus term | Electronic books. |
776 08 - ADDITIONAL PHYSICAL FORM ENTRY | |
Relationship information | Print version: |
Main entry heading | Redbooks, IBM |
Title | IBM Tivoli Storage Area Network Manager |
Place, publisher, and date of publication | Durham : I B M,c2001 |
International Standard Book Number | 9780738499970 |
797 2# - LOCAL ADDED ENTRY--CORPORATE NAME (RLIN) | |
Corporate name or jurisdiction name as entry element | ProQuest (Firm) |
856 40 - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="https://ebookcentral.proquest.com/lib/orpp/detail.action?docID=3306753">https://ebookcentral.proquest.com/lib/orpp/detail.action?docID=3306753</a> |
Public note | Click to View |
No items available.